what does soh stand for

In batteries, SOH stands for State of Health. It describes a battery’s current condition compared with its original or reference performance, usually expressed as a percentage. A battery with 80% capacity-based SOH retains approximately 80% of its original capacity. SOH helps determine battery degradation, available energy, backup runtime and whether replacement is necessary.

What Does SOH Stand For in a Battery?

SOH stands for State of Health in lithium-ion batteries, LiFePO4 batteries, lead-acid batteries, electric vehicles and battery energy storage systems (BESS). It indicates how much of a battery’s original performance remains after aging and use.

Battery SOH generally considers several performance characteristics:

Health IndicatorWhat It MeasuresWhy It Matters
Remaining capacityHow much electrical charge the battery can storeDetermines available capacity and runtime
Energy retentionHow much energy the battery can deliverDetermines usable energy in kWh
Internal resistanceResistance to current flow inside the batteryAffects voltage drop, heat and power delivery
Power capabilityHow much power the battery can supplyDetermines whether the battery can support demanding loads
Self-dischargeEnergy or charge lost during inactivityHelps identify abnormal energy loss
Cell consistencyDifferences in individual cell behaviorHelps identify cells that may limit pack performance

How Much Capacity Remains at Different SOH Levels?

A battery’s remaining capacity can be estimated by multiplying its reference capacity by its capacity-based SOH. A 100Ah battery at 80% SOH retains approximately 80Ah under equivalent measurement conditions, while a battery with 10kWh of reference energy at 80% energy-based SOH retains approximately 8kWh.

Battery SOH100Ah Battery5kWh Battery10kWh BatteryCapacity or Energy Loss
100%100Ah5.00kWh10.00kWh0%
95%95Ah4.75kWh9.50kWh5%
90%90Ah4.50kWh9.00kWh10%
85%85Ah4.25kWh8.50kWh15%
80%80Ah4.00kWh8.00kWh20%
70%70Ah3.50kWh7.00kWh30%
60%60Ah3.00kWh6.00kWh40%

The Avepower 51.2V 100Ah wall-mounted solar battery has a calculated nominal energy of 5.12kWh and uses LiFePO4 chemistry for residential solar storage and backup power. If its energy-based SOH were to decline to 85% relative to a 5.12kWh reference, its remaining energy would be approximately 4.35kWh before accounting for operating reserves and conversion losses.

avepwoer 51.2v 100ah 5kwh bttery

Avepower 51.2V 100Ah 5kWh Battery 

51.2V 100Ah 5kWh wall mounted LiFePO4 solar battery features a slim design, 100A charge and discharge current, 16-unit parallel expansion, and 8,000+ cycles for residential energy storage.

What Is a Good Battery SOH Percentage?

Capacity-based SOH above 90% generally indicates limited capacity loss relative to the reference value. An SOH of 80% may still be acceptable if the battery meets its operating requirements.

Capacity-Based SOHCapacity LossPractical InterpretationRecommended Action
95%–100%0%–5%Close to reference capacityContinue normal monitoring
90%–Below 95%5%–10%Limited capacity degradationCheck long-term trends
80%–Below 90%10%–20%Noticeable capacity reductionReassess backup runtime and load requirements
70%–Below 80%20%–30%Substantial capacity reductionEvaluate continued suitability and replacement options
Below 70%More than 30%Significant capacity lossConduct a detailed performance assessment

Is 80% Battery SOH Still Good?

Yes. A battery with 80% capacity-based SOH can remain suitable for solar energy storage if its remaining energy, power capability and operating condition meet the application’s requirements. Although 80% capacity retention is commonly used as a cycle-life endpoint, it does not mean the battery has suddenly stopped functioning.

A 10kWh battery retaining 8kWh may still support a household that requires only 5kWh of daily stored energy. However, the same battery may no longer meet the requirements of a backup system that depends on nearly its full original capacity.

soc vs soh understanding your battery

What Is the Difference Between SOH and SOC?

SOH measures a battery’s health relative to its reference condition, while SOC (State of Charge) measures how much charge remains relative to its current available capacity. A degraded battery can reach 100% SOC even when its maximum capacity has declined to 80% SOH.

ParameterSOHSOC
Full nameState of HealthState of Charge
Main purposeBattery health assessmentCurrent charge level
ReferenceOriginal or specified performanceCurrent available capacity
Main influencing factorsAging, degradation and operating historyCharging and discharging
Typical useMaintenance and replacement planningDaily energy management

Consider a 100Ah battery with 80% capacity-based SOH:

  • At 100% SOC, it holds approximately 80Ah.
  • At 50% SOC, it holds approximately 40Ah.
  • At 25% SOC, it holds approximately 20Ah.

Charging the battery changes its SOC, but it does not restore the original 100Ah capacity lost through irreversible degradation.

Understanding the difference between SOH and SOC is important when interpreting battery monitoring data and estimating available backup power.

How to Check the State of Health of a Battery

Battery SOH can be assessed using BMS diagnostic data, controlled capacity tests, internal resistance measurements and operating history.

Testing MethodWhat It Can DetermineMain LimitationBest Application
BMS diagnostic readingEstimated battery health and degradation trendsDepends on the estimation algorithmRoutine monitoring
Controlled capacity testAvailable discharge capacity in AhRequires suitable equipment and test conditionsCapacity verification
Controlled energy testDelivered energy in Wh or kWhRequires accurate energy measurementSolar battery and BESS evaluation
Internal resistance testResistance growth and current delivery limitationsCannot directly establish remaining capacityPower performance assessment
Voltage and load testVoltage sag and abnormal behaviorInfluenced by SOC, temperature and loadPreliminary diagnosis
Operating history analysisUsage patterns and degradation trendsRequires reliable historical recordsPreventive maintenance

What Causes Battery SOH to Decrease?

Battery SOH decreases primarily because rechargeable batteries undergo calendar aging and cycle aging. Calendar aging occurs over time, even when a battery is not used, while cycle aging results from charging and discharging.

Calendar Aging vs. Cycle Aging

Calendar aging describes time-dependent chemical degradation, whereas cycle aging describes deterioration associated with repeated energy throughput. Both processes can occur simultaneously, which means a battery with relatively few charge cycles may still experience substantial capacity loss after prolonged storage or exposure to unfavorable temperatures.

Degradation FactorPotential EffectRecommended Action
High operating temperatureAccelerated chemical agingMaintain manufacturer-approved operating temperatures
Charging at excessively low temperaturesPotential lithium plating in susceptible lithium-ion cellsFollow minimum charging temperature limits
Deep dischargeIncreased cycling stress under some operating conditionsUse the recommended SOC operating window
High charge or discharge currentIncreased heat and electrical stressStay within rated current limits
Prolonged storage at unfavorable SOCAccelerated calendar aging in some chemistriesFollow storage SOC recommendations
Cell imbalanceReduced accessible pack capacity or premature shutdownInvestigate persistent cell voltage differences
Repeated operation outside voltage limitsAccelerated degradation or permanent damageUse approved charging settings and BMS protection

Understanding battery charge and discharge rates and depth of discharge can help system owners reduce unnecessary battery stress.

how does soh affect solar battery backup time

How Does SOH Affect Solar Battery Backup Time?

A declining energy-based SOH reduces the amount of energy available for household backup, even when the battery is fully charged. Actual backup time also depends on the permitted SOC operating window, inverter efficiency, system consumption and electrical load. These factors must be included when estimating runtime.

A simplified runtime calculation is:

Backup Time (hours) = Reference Battery Energy (kWh) × Energy-Based SOH × Usable SOC Window × Discharge Efficiency ÷ Average Load (kW)

Assume a residential solar battery system has the following characteristics:

  • Reference battery energy: 10kWh.
  • Operating SOC window: 100% to 20%, or 80%.
  • Effective discharge efficiency: 92%.
  • Average household load: 1kW.
  • No solar generation or grid charging during backup operation.

Battery SOH & Runtime Calculator

Estimate remaining battery energy, usable AC energy, and backup runtime based on battery State of Health (SOH).

Interactive calculator loading. If the values do not update, please check whether JavaScript is enabled.
Energy retention relative to the battery’s reference energy.
An SOC range of 20%–100% provides an 80% usable window.
Estimated battery-to-AC-load efficiency, including applicable conversion losses.
Remaining Battery Energy
8.00 kWh
Remaining energy after battery degradation.
Estimated Usable AC Energy
5.89 kWh
After operating reserves and discharge losses.
Estimated Backup Time
5.89 hours
At the specified constant AC load.
Energy Lost to Degradation
2.00 kWh
Energy lost relative to the reference value.
Battery Energy Distribution 58.88% Available
Available AC Energy 58.88%
Reserve & Losses 21.12%
Battery Degradation 20.00%
Calculation Formula

Remaining Energy = Reference Energy × SOH

Usable AC Energy = Remaining Energy × Usable SOC Window × Discharge Efficiency

Backup Time = Usable AC Energy × 1,000 ÷ AC Load (W)

Percentages are converted to decimal values.
Calculation Notes: Results are estimates based on energy-based SOH, constant AC load, and no incoming solar or grid charging. Reference battery energy should be specified before deducting the selected operating reserve and applicable discharge losses. Actual runtime may vary with temperature, inverter efficiency, standby consumption, battery condition, and BMS operating limits. The connected load must remain within the battery and inverter’s rated power limits. This calculator estimates runtime and does not independently measure battery SOH.
Battery SOHRemaining Battery EnergyEstimated AC Energy AvailableBackup Time at 1kWBackup Time at 2kW
100%10.00kWh7.36kWh7.36 hours3.68 hours
95%9.50kWh6.99kWh6.99 hours3.50 hours
90%9.00kWh6.62kWh6.62 hours3.31 hours
85%8.50kWh6.26kWh6.26 hours3.13 hours
80%8.00kWh5.89kWh5.89 hours2.94 hours
70%7.00kWh5.15kWh5.15 hours2.58 hours

At 80% energy-based SOH, the battery provides approximately 5.89 hours of backup at a constant 1kW load, compared with 7.36 hours when new.

The efficiency and operating window used here are illustrative assumptions, not universal specifications. The calculation assumes the reference energy is measured before applying the operating window and discharge losses. If the manufacturer already specifies usable AC energy within that window, those factors must not be deducted again.

Real backup time may differ because of changing appliance loads, inverter standby consumption, temperature, battery voltage and BMS current restrictions.

Is a Used Battery With Lower SOH Worth Buying?

A used battery with lower SOH may be worth purchasing if its verified remaining energy, power capability, safety condition and expected service life meet the intended application at a suitable total cost.

One initial comparison metric is:

Cost per Remaining kWh = Purchase Price ÷ Verified Remaining Energy

The following is a hypothetical purchasing comparison in US dollars for a buyer in the United States. These figures are illustrative and are not current retail quotations.

SpecificationNew Battery AUsed Battery BUsed Battery C
Reference energy10kWh10kWh10kWh
Energy-based SOH100%85%70%
Remaining energy10kWh8.5kWh7kWh
Assumed purchase priceUS$3,000US$2,200US$2,000
Cost per remaining kWhUS$300US$258.82US$285.71

Battery C has the lowest purchase price, but Battery B offers the lowest initial cost per remaining kWh.

How Can You Maintain Battery State of Health?

Battery SOH can be maintained by operating within manufacturer-approved temperature, voltage, current and SOC limits, avoiding unnecessary electrical stress and investigating abnormal performance early. Although normal battery aging cannot be eliminated, suitable operating conditions can help reduce avoidable degradation.

Routine monitoring is particularly important in solar energy storage systems that charge and discharge frequently. Understanding the factors affecting solar battery lifespan can help owners establish appropriate operating and maintenance practices.

Conclusion

SOH stands for State of Health and describes how a battery’s current condition compares with its original or specified reference performance. In solar energy storage, understanding SOH helps users estimate remaining capacity, calculate backup runtime, evaluate degradation and make informed maintenance or replacement decisions.

The most useful battery assessment combines verified capacity or energy measurements with power capability, operating history, physical condition and system requirements.

If you are planning a new solar storage installation or evaluating replacement battery capacity, Avepower offers LiFePO4 home energy storage batteries and technical configuration support based on your required energy, backup loads and inverter specifications.

Avepower home energy storage battery

Take Control of Your Energy with Avepower!

Reliable home solar battery solutions with OEM/ODM customization and in-house manufacturing, tailored to the needs of distributors, installers, and energy partners.

FAQ

Can a battery have more than 100% SOH?

Yes. A capacity-based SOH calculation can exceed 100% when the measured capacity is greater than the nominal reference capacity. Manufacturing tolerances and test conditions may contribute to this result. Some BMS algorithms cap the displayed value at 100%.

Can battery SOH be restored?

Normal irreversible battery degradation cannot generally be reversed by charging or recalibration. However, recalibration, temperature normalization or correction of cell imbalance may improve the reported SOH or accessible capacity without reversing underlying chemical aging.

Can battery SOH be calculated from the number of charge cycles?

Not accurately from cycle count alone. Battery degradation also depends on temperature, calendar age, discharge depth, current and chemistry. Cycle count provides useful context but cannot replace capacity measurements and condition assessment.

Does battery SOH affect charging speed?

It can. Aging may increase internal resistance or reduce allowable charging current, causing the BMS to limit charging power. However, capacity-based SOH alone cannot predict charging speed because power limits and temperature also influence charging performance.

Picture of Ryan

Ryan

Ryan is an energy expert with over 10 years of experience in the field of battery energy storage and renewable solutions. He is passionate about developing efficient, safe, and sustainable battery systems. In his spare time, he enjoys adventure and exploring.

Learn more about Ryan
Share on social:

Leave a Comment

Your email address will not be published. Required fields are marked *

lifepo4 home solar battery for wholesale

About Avepower

Backed by 10+ years of battery manufacturing experience and a 20,000㎡ factory, Avepower delivers reliable LiFePO4 energy storage solutions worldwide.

Send Your Requirements

Get battery type, capacity, and solution suggestions in one quick form.

Get Expert Battery Selection Support

For Distributors

Avepower supply quality products with stable support to grow your business.

For Wholesalers

Get bulk supply, competitive pricing, and reliable product availability.

For Installers

Easy-to-install systems with strong performance and full support.

Energy Storage Solution Quote

Battery Quote Request

Get a Quote & Download Catalog

Custom Energy Storage Solutions

OEM & ODM services designed for installers, wholesalers, distributors, and global brands.

avepower energy storage battery system manufacturing factory (1)

Get Avepower Catalog

Full energy storage specs and details in one PDF. Enter your email and we’ll send it to you.

Get Battery Quote & Solution